JWST detects pulsing infrared light from magnetar 4U 0142+61

The Webb telescope has detected pulsed infrared light from the magnetar 4U 0142+61 for the first time. Pulsations at a wavelength near 4.1 micrometers match the neutron star’s 8.7-second spin and line up in phase with its hard X-ray emission. The result adds to evidence that the object’s infrared glow comes from its magnetosphere rather than from a surrounding fallback disk. It is reported in a paper in The Astrophysical Journal.
A short, coarse observation
JWST’s Near-Infrared Camera (NIRCam) observed the magnetar on 2024 August 18 for 33 minutes in timing mode, with a time resolution of 2.5 seconds. In the F410M filter, centered at 4.08 μm, the source had a flux density of 22.9 ± 0.6 microjanskys. A periodogram of the light curve showed pulsations at 115.059 ± 0.035 millihertz, consistent with the spin frequency predicted by an X-ray timing solution from NICER monitoring.
A second peak, near 168 millihertz, turned out to be an alias produced by the sampling rate. Its presence implies that the infrared signal contains a second harmonic. A test region taken from the background did not show the signal.
The folded profile has a single broad peak per cycle, with a measured peak-to-trough pulsed fraction of 8% ± 1%. A time resolution of 2.5 seconds is about 29% of the spin period, so it smooths the profile and suppresses the pulsations. The authors therefore set a lower limit of about 10% on the true pulsed fraction and cannot rule out a double-peaked profile like the one seen in X-rays.
Alignment with hard X-rays
The team compared the infrared profile with NICER and NuSTAR X-ray data, folded using a phase-connected timing solution by Han-Long Peng and colleagues. The infrared peak falls slightly ahead of the hard X-ray peak. The measured offsets are consistent with zero within 1–2σ, given a phase uncertainty of roughly 0.064 for the infrared peak. A lag would have pointed to X-ray light being reprocessed in material beyond the magnetosphere, such as a disk, and none is established here. The authors say that pinning down the relative phase will require infrared data with much better time resolution.
The finding fits earlier JWST work by Jonathan Hare and colleagues, who found a featureless power-law infrared spectrum that did not support the fallback disk proposed from Spitzer data in 2006. Refitting that dataset with updated calibration gave essentially the same parameters.
Possible variability
The F410M flux is about 20% below what the earlier spectral fit predicts, which suggests the infrared emission varies. Renormalizing the model to the new flux lowers the unabsorbed 1.4–11 μm luminosity from 7.3 × 1031 to 6.1 × 1031 erg/s at a distance of 3.6 kiloparsecs.
NICER data show a small rise in X-ray flux around the time of a glitch in the timing solution, between the two JWST observations. The X-ray-to-infrared flux ratio was about 1,000 in both. The authors say a correlation would need higher-cadence infrared monitoring to confirm.
The authors say no existing disk model explains the broad power-law spectrum, the variability and the near-alignment with the hard X-ray pulse together. They add that the mechanism and location of magnetar infrared-optical emission remain unclear. Possibilities include curvature radiation from the inner magnetosphere and synchrocyclotron emission farther out. They describe the observation as exploratory and say that follow-up with better time resolution should characterize the pulsations more fully.
Source: doi.org




